Pile Axial Capacity From Shaft and Base Resistance

Pile axial capacity in compression is commonly described through shaft resistance along the embedded length and base resistance at the tip.

Pile axial capacity in compression is commonly described through shaft resistance along the embedded length and base resistance at the tip. The two mechanisms mobilize as displacement increases and can require different movements to develop their full resistance.

Track resistance by layer

Calculate shaft contribution for each soil unit using a method appropriate to the pile type and installation. Evaluate tip resistance with the material around and below the base, including weak layers within its influence. Compare predicted working-load settlement with a load-transfer model or representative load test. The weight convention, groundwater conditions and reference load level should be explicit when comparing calculations.

Why can shaft resistance mobilize first?

Part of the shaft may develop substantial friction at small relative movement while developing large base resistance requires greater movement at the tip.