Skip to content
SOILIUM

Site investigation · 1 min read

SPT N Values and Why Correction Matters

The SPT N value is generally the blow count for the final 300 mm of a standard 450 mm sampler drive after the initial seating interval.

The SPT N value is generally the blow count for the final 300 mm of a standard 450 mm sampler drive after the initial seating interval. Logs should retain the original increments and explain short penetration or refusal under the applicable test procedure.

Keep corrected values traceable

Hammer energy affects the recorded resistance, so correlations often require N60 normalized to a reference energy efficiency, with other equipment corrections as specified by the chosen method. A separate overburden normalization may be used for correlations stated in terms of (N₁)₆₀. Preserve raw counts, hammer information and each correction. Gravel can create abrupt high readings, so compare them with recovered material and adjacent information before inferring a strong continuous layer.

What should a log say when SPT refusal is recorded?

Keep the blow count and actual penetration for the affected interval, with context from recovered material and the refusal criterion used.

References